{"id":4442,"date":"2026-08-19T22:04:52","date_gmt":"2026-08-19T19:04:52","guid":{"rendered":"https:\/\/atlasaqua.com.tr\/en\/?p=4442"},"modified":"2026-08-21T19:14:00","modified_gmt":"2026-08-21T16:14:00","slug":"water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82","status":"publish","type":"post","link":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/","title":{"rendered":"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4442\" class=\"elementor elementor-4442\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-248bfb93 elementor-section-boxed elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"248bfb93\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-442aec9e\" data-id=\"442aec9e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-inner-section elementor-element elementor-element-7db920ed elementor-section-full_width elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"7db920ed\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-7c8f45d8\" data-id=\"7c8f45d8\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4e3e544e elementor-widget elementor-widget-heading\" data-id=\"4e3e544e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11f05bd4 elementor-widget elementor-widget-text-editor\" data-id=\"11f05bd4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Water quality in RAS is a network of interacting processes. Temperature and pH control the toxic NH\u2083 fraction of TAN; alkalinity supports biofilter pH stability; CO\u2082 affects oxygen use; and solids increase microbial oxygen demand and disease pressure.<\/p>\n<h2><b>Why is water quality central to RAS?<\/b><\/h2>\n<p>In intensive production, fish, feed and the biofilter continuously consume oxygen and generate metabolites in the same water. A flow-through facility can export much of that load with new water; in a RAS, treatment must keep pace with production. Measurement is therefore a direct part of capacity and operating management\u2014not merely a laboratory check.<\/p>\n<h2><span style=\"color: #00162e; font-family: Montserrat, sans-serif; font-weight: bolder;\">Read more about:\u00a0<\/span><b><a href=\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/18\/ras-design-by-fish-species-trout-carp-sturgeon-and-tilapia\/\">RAS Design by Fish Species: Trout, Carp, Sturgeon and Tilapia<\/a><\/b><\/h2>\n<p>Targets must be set for the fish species, life stage, temperature, salinity and operating policy. One generic table of \u2018ideal values\u2019 found online should not be applied to every RAS project.<\/p>\n<h2><span style=\"color: #00162e; font-family: Montserrat, sans-serif; font-weight: bolder;\">Read more about:\u00a0<\/span><b><a href=\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/how-does-a-ras-system-work-water-treatment-stages-and-process-flow\/\">How Does a RAS System Work? Water-Treatment Stages and Process Flow<\/a><\/b><\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-207e6c93 elementor-section-boxed elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"207e6c93\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-27c7ba7a\" data-id=\"27c7ba7a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-inner-section elementor-element elementor-element-2f153af1 elementor-section-boxed elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"2f153af1\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-7003bce3 animated-slow\" data-id=\"7003bce3\" data-element_type=\"column\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;,&quot;animation_delay&quot;:5000}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-23d7ebcb elementor-widget elementor-widget-image\" data-id=\"23d7ebcb\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/filtration-equipment\/ras-box\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"534\" src=\"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp\" class=\"elementor-animation-grow attachment-large size-large wp-image-4320\" alt=\"RAS energy use for pumps, blowers, oxygen, UV and temperature control\" srcset=\"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp 1024w, https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--300x200.webp 300w, https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--768x512.webp 768w, https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3-.webp 1500w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-483e3df8 animated-slow\" data-id=\"483e3df8\" data-element_type=\"column\" data-settings=\"{&quot;animation&quot;:&quot;none&quot;,&quot;animation_delay&quot;:5000}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6d5b727c elementor-widget elementor-widget-image\" data-id=\"6d5b727c\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/filtration-equipment\/ras-box\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"534\" src=\"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-kompakt-filtre-15m3--1024x683.webp\" class=\"elementor-animation-grow attachment-large size-large wp-image-4318\" alt=\"Atlas Aqua recirculating fish farm projects for different fish species\" srcset=\"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-kompakt-filtre-15m3--1024x683.webp 1024w, https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-kompakt-filtre-15m3--300x200.webp 300w, https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-kompakt-filtre-15m3--768x512.webp 768w, https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-kompakt-filtre-15m3-.webp 1500w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-5c8a887a elementor-section-boxed elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"5c8a887a\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-314dfe8a\" data-id=\"314dfe8a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-inner-section elementor-element elementor-element-68741c6a elementor-section-full_width elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"68741c6a\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-4491ae4b\" data-id=\"4491ae4b\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-341e3e04 elementor-widget elementor-widget-text-editor\" data-id=\"341e3e04\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><b>Dissolved oxygen (DO)<\/b><\/h2>\n<p class=\"p2\">DO is one of the fastest-changing critical parameters. Fish respiration, post-feeding metabolism, biofilter nitrification and organic degradation all consume oxygen. A high tank-inlet value is not sufficient; the minimum tank-outlet value and the system response during feeding peaks must be monitored.<\/p>\n<p class=\"p3\">At high densities, pure-oxygen transfer may use an <a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/aeration-equipment\/oxygen-cone\/\"><span class=\"s1\">oxygen cone<\/span><\/a> or <a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/aeration-equipment\/nanob-aquaculture\/\"><span class=\"s1\">NANOB<\/span><\/a>. Selection must be based on water flow, inlet\/outlet DO difference, pressure and verified transfer efficiency\u2014not the target gas dose alone.<\/p>\n<h2><b>pH and alkalinity<\/b><\/h2>\n<p class=\"p2\">pH affects fish physiology, biofilter activity and the NH\u2083\/NH\u2084\u207a balance. Nitrification consumes alkalinity and tends to lower pH. Alkalinity trend should therefore be monitored alongside pH, and buffering chemicals should be dosed in a controlled and recorded manner.<\/p>\n<p class=\"p4\"><span class=\"s2\"><b>Critical relationship: <\/b><\/span>At the same TAN concentration, increasing temperature and pH can increase the toxic unionised-ammonia (NH\u2083) fraction.<\/p>\n<h2><b>TAN and ammonia<\/b><\/h2>\n<p class=\"p2\">TAN is the sum of ionised NH\u2084\u207a and unionised NH\u2083. Part of the nitrogen in feed enters the water as TAN. Its trend must be interpreted with feed input, biofilter capacity, biofilm maturity, temperature, pH, alkalinity and DO.<\/p>\n<p class=\"p3\">A TAN increase does not automatically mean that the <a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/filtration-equipment\/biofilter\/\"><span class=\"s1\">biofilter<\/span><\/a> is undersized. A sudden feed increase, low alkalinity, low DO, chemical exposure, biofilm loss or reduced actual flow can create the same result.<\/p>\n<h2><span style=\"color: #00162e; font-family: Montserrat, sans-serif; font-weight: bolder;\">Read more about:\u00a0<\/span><b><a href=\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/how-to-size-a-ras-project-feed-load-biomass-tan-and-flow-calculations\/\">How to Size a RAS Project: Feed Load, Biomass, TAN and Flow Calculations<\/a><\/b><\/h2>\n<h2><b>Nitrite and nitrate<\/b><\/h2>\n<p class=\"p2\">Nitrite is an intermediate product of nitrification and can impair oxygen transport in fish blood. New-system start-up, sudden loading or biofilter imbalance may raise nitrite. The chloride-to-nitrite relationship and species tolerance should be assessed by an aquaculture specialist.<\/p>\n<p class=\"p3\">Nitrate is generally less acutely toxic than TAN or nitrite, but it accumulates in intensive RAS. Control may use make-up-water exchange, denitrification, production strategy or integrated plant systems. The operating limit must be species- and life-stage-specific.<\/p>\n<h2><b>Carbon dioxide (CO\u2082)<\/b><\/h2>\n<p class=\"p2\">Fish, the biofilter and waterborne microorganisms produce CO\u2082 through respiration. High CO\u2082 can challenge oxygen transport and use and can affect pH. Fish gathering at the tank inlet or showing abnormal respiration despite apparently normal DO should trigger investigation of CO\u2082 and overall gas balance.<\/p>\n<p class=\"p3\">A <a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/filtration-equipment\/degassign\/\"><span class=\"s1\">degasser<\/span><\/a> must be sized for water-air contact area, air flow, water distribution and hydraulic loading. The presence of a blower alone does not demonstrate effective degassing.<\/p>\n<h2><b>Solids, turbidity and organic load<\/b><\/h2>\n<p class=\"p3\">Faeces and uneaten feed should be removed before disintegration. A <a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/filtration-equipment\/drum-filter\/\"><span class=\"s1\">drum filter<\/span><\/a> separates solids early, reducing heterotrophic bacterial pressure, oxygen consumption and fine-particle formation in the biofilter. In seawater systems, a <a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/filtration-equipment\/protein-skimmer\/\"><span class=\"s1\">protein skimmer<\/span><\/a> can assist with dissolved and fine organic matter.<\/p>\n<h2><b>Temperature, salinity and disinfection<\/b><\/h2>\n<p class=\"p2\">Temperature changes fish growth and oxygen demand, water oxygen-carrying capacity and bacterial reaction rate. Salinity affects oxygen solubility, nitrite toxicity and material selection. Freshwater and marine RAS should not automatically use the same equipment materials or chemical-control approach.<\/p>\n<h2><span style=\"color: #00162e; font-family: Montserrat, sans-serif; font-weight: bolder;\">Read more about:\u00a0<\/span><b><a href=\"https:\/\/atlasaqua.com.tr\/en\/recirculating-fish-farm-setup-cost-the-technical-factors-behind-the-price\/\">Recirculating Fish Farm Setup Cost: The Technical Factors Behind the Price<\/a><\/b><\/h2>\n<p class=\"p2\"><span class=\"s1\"><a href=\"https:\/\/atlasaqua.com.tr\/en\/products\/filtration-equipment\/uv-filter\/\">UV disinfection<\/a><\/span> is a barrier that reduces free-circulating microorganisms. Performance depends on water transmittance, turbidity, UV dose, actual flow and lamp\/sleeve maintenance. UV does not replace quarantine, hygiene or veterinary programmes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-c1f529c elementor-section-boxed elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"c1f529c\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-637193fd\" data-id=\"637193fd\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-586e8753 elementor-widget elementor-widget-heading\" data-id=\"586e8753\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How should a monitoring plan be structured?\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58ad2ce9 wpr-table-align-items-center wpr-data-table-type-custom elementor-widget elementor-widget-wpr-data-table\" data-id=\"58ad2ce9\" data-element_type=\"widget\" data-widget_type=\"wpr-data-table.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\n\t\t\t\t\n\t\t<div class=\"wpr-table-container\">\n\t\t<div class=\"wpr-table-inner-container \" data-table-sorting=\"no\" data-custom-pagination=\"no\" data-row-pagination=\"\" data-entry-info=\"no\" data-rows-per-page=\"\">\n\n\t\t\n\t\t\t<table class=\"wpr-data-table\" id=\"wpr-data-table\">\n\t\t\t\t\t\t\t\t\n\t\t\t\t<thead>\n\t\t\t\t\t<tr class=\"wpr-table-head-row wpr-table-row\">\n\t\t\t\t\t\n\t\t\t\t\t\t<th class=\"wpr-table-th elementor-repeater-item-c90c9e0\" colspan=\"1\">\n\t\t\t\t\t\t\t<div class=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">Monitoring level<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/th>\n\t\t\t\t\t\t\n\t\t\t\t\t\t<th class=\"wpr-table-th elementor-repeater-item-739e8dc\" colspan=\"1\">\n\t\t\t\t\t\t\t<div class=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">Example parameters and purpose<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/th>\n\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t\t<\/thead>\n\n\t\t\t\t<tbody>\n\t\t\t\t\t\t\t\t\t<tr class=\"wpr-table-body-row wpr-table-row elementor-repeater-item-f0ac809 wpr-odd\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-d084621 wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tContinuous \/ online\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-5af0445 wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tDO, temperature, pH, water level and pump\/blower status for rapid alarm and control\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t<tr class=\"wpr-table-body-row wpr-table-row elementor-repeater-item-43ae6f5 wpr-even\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-ef6a1a9 wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tDaily\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-fbcf670 wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tPortable verification of tank inlet\/outlet DO, temperature, behaviour, flow and feed record\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t<tr class=\"wpr-table-body-row wpr-table-row elementor-repeater-item-662d28e wpr-odd\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-88ce73d wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tWeekly or load-based\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-1a7e201 wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tTAN, nitrite, nitrate, alkalinity and TSS for biofilter and water-renewal trends\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t<tr class=\"wpr-table-body-row wpr-table-row elementor-repeater-item-a12d707 wpr-even\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-650c06e wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tPeriodic\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-df80d4c wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tSource water, microbiology, hardness, iron\/manganese, chloride and instrument calibration\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t<tr class=\"wpr-table-body-row wpr-table-row elementor-repeater-item-4662fcb wpr-odd\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-893457d wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tPost-event\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"elementor-repeater-item-a2c4499 wpr-table-td\">\n\n\t\t\t\t\t\t\t\t<div class=\"wpr-td-content-wrapper \">\n\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/royal-elementor-addons.com\/\" target=\"_blank\">\n\t\t\t\t\t\t\t\t\t \n\t\t\t\t\t\t\t\t\t\t\t<span class=\"wpr-table-text\">\n\t\t\t\t\t\t\t\t\t\t\t\tRoot-cause analysis after alarms, mortality, feed stoppage or chemical treatment\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t<\/tbody>\n\t\t\t<\/table>\n\t\t<\/div>\n\t\t<\/div>\n    \t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-590b6d19 elementor-section-boxed elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"590b6d19\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-439e87b9\" data-id=\"439e87b9\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-inner-section elementor-element elementor-element-24bdd994 elementor-section-full_width elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no\" data-id=\"24bdd994\" data-element_type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[],&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-5200ad83\" data-id=\"5200ad83\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-26f2dddb elementor-widget elementor-widget-text-editor\" data-id=\"26f2dddb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\"><span class=\"s1\"><b>\u00a0<\/b><\/span><\/p>\n<h2><span style=\"color: #00162e; font-family: Montserrat, sans-serif; font-weight: bolder;\">Read more about:\u00a0<\/span><b><a href=\"https:\/\/atlasaqua.com.tr\/en\/blog\/ras-energy-efficiency-redundancy-emergency-design\/\">Energy Efficiency, Redundancy and Emergency Design in RAS<\/a><\/b><\/h2>\n<p class=\"p1\"><span class=\"s1\"><b>Monitoring principle: <\/b><\/span>A sensor is not enough. Define its location, calibration interval, alarm threshold, responsible person and the action required after an alarm.<\/p>\n<h2><b>Frequently asked questions<\/b><\/h2>\n<h2><b>What is the most important RAS water-quality parameter?<\/b><\/h2>\n<p class=\"p4\">DO is often the fastest-changing critical parameter, but it is not sufficient alone. CO\u2082, TAN, nitrite, pH, alkalinity, temperature and flow must be managed together.<\/p>\n<h2><b>Why can fish be stressed when TAN is normal?<\/b><\/h2>\n<p class=\"p4\">Possible causes include low DO, high CO\u2082, nitrite, temperature, suspended solids, gas supersaturation or disease.<\/p>\n<h2><b>Does falling pH prove that the biofilter is working?<\/b><\/h2>\n<p class=\"p4\">Nitrification consumes alkalinity and can lower pH, but source water, CO\u2082 and chemical dosing also affect it. Interpret pH with TAN, nitrite and alkalinity.<\/p>\n<h2><b>Does UV prevent every disease?<\/b><\/h2>\n<p class=\"p5\">No. UV only reduces free microorganisms that pass through the unit at the required dose. Quarantine, hygiene, stock management and veterinary oversight remain necessary.<\/p>\n<p class=\"p6\"><span class=\"s1\"><b>FOR YOUR PROJECT: <\/b><\/span>To design species-specific water-quality targets, sensor points, alarm thresholds and treatment capacity, <a href=\"https:\/\/atlasaqua.com.tr\/en\/contact-us\/\"><span class=\"s2\">Contact Atlas Aqua.<\/span><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 Water quality in RAS is a network of interacting processes. Temperature and pH control the toxic NH\u2083 fraction of TAN; alkalinity supports biofilter pH stability; CO\u2082 affects oxygen use; and solids increase microbial oxygen demand and disease pressure. Why is water quality central to RAS? In intensive production, fish, feed and the biofilter continuously consume oxygen and generate metabolites in the same water. A flow-through facility can export much of that load with new water; in a RAS, treatment must keep pace with production. Measurement is therefore a direct part of capacity and operating management\u2014not merely a laboratory check. Read more about:\u00a0RAS Design by Fish Species: Trout, Carp, Sturgeon and Tilapia Targets must be set for the fish species, life stage, temperature, salinity and operating policy. One generic table of \u2018ideal values\u2019 found online should not be applied to every RAS project. Read more about:\u00a0How Does a RAS System Work? Water-Treatment Stages and Process Flow Dissolved oxygen (DO) DO is one of the fastest-changing critical parameters. Fish respiration, post-feeding metabolism, biofilter nitrification and organic degradation all consume oxygen. A high tank-inlet value is not sufficient; the minimum tank-outlet value and the system response during feeding peaks must be monitored. At high densities, pure-oxygen transfer may use an oxygen cone or NANOB. Selection must be based on water flow, inlet\/outlet DO difference, pressure and verified transfer efficiency\u2014not the target gas dose alone. pH and alkalinity pH affects fish physiology, biofilter activity and the NH\u2083\/NH\u2084\u207a balance. Nitrification consumes alkalinity and tends to lower pH. Alkalinity trend should therefore be monitored alongside pH, and buffering chemicals should be dosed in a controlled and recorded manner. Critical relationship: At the same TAN concentration, increasing temperature and pH can increase the toxic unionised-ammonia (NH\u2083) fraction. TAN and ammonia TAN is the sum of ionised NH\u2084\u207a and unionised NH\u2083. Part of the nitrogen in feed enters the water as TAN. Its trend must be interpreted with feed input, biofilter capacity, biofilm maturity, temperature, pH, alkalinity and DO. A TAN increase does not automatically mean that the biofilter is undersized. A sudden feed increase, low alkalinity, low DO, chemical exposure, biofilm loss or reduced actual flow can create the same result. Read more about:\u00a0How to Size a RAS Project: Feed Load, Biomass, TAN and Flow Calculations Nitrite and nitrate Nitrite is an intermediate product of nitrification and can impair oxygen transport in fish blood. New-system start-up, sudden loading or biofilter imbalance may raise nitrite. The chloride-to-nitrite relationship and species tolerance should be assessed by an aquaculture specialist. Nitrate is generally less acutely toxic than TAN or nitrite, but it accumulates in intensive RAS. Control may use make-up-water exchange, denitrification, production strategy or integrated plant systems. The operating limit must be species- and life-stage-specific. Carbon dioxide (CO\u2082) Fish, the biofilter and waterborne microorganisms produce CO\u2082 through respiration. High CO\u2082 can challenge oxygen transport and use and can affect pH. Fish gathering at the tank inlet or showing abnormal respiration despite apparently normal DO should trigger investigation of CO\u2082 and overall gas balance. A degasser must be sized for water-air contact area, air flow, water distribution and hydraulic loading. The presence of a blower alone does not demonstrate effective degassing. Solids, turbidity and organic load Faeces and uneaten feed should be removed before disintegration. A drum filter separates solids early, reducing heterotrophic bacterial pressure, oxygen consumption and fine-particle formation in the biofilter. In seawater systems, a protein skimmer can assist with dissolved and fine organic matter. Temperature, salinity and disinfection Temperature changes fish growth and oxygen demand, water oxygen-carrying capacity and bacterial reaction rate. Salinity affects oxygen solubility, nitrite toxicity and material selection. Freshwater and marine RAS should not automatically use the same equipment materials or chemical-control approach. Read more about:\u00a0Recirculating Fish Farm Setup Cost: The Technical Factors Behind the Price UV disinfection is a barrier that reduces free-circulating microorganisms. Performance depends on water transmittance, turbidity, UV dose, actual flow and lamp\/sleeve maintenance. UV does not replace quarantine, hygiene or veterinary programmes. How should a monitoring plan be structured? Monitoring level Example parameters and purpose Continuous \/ online DO, temperature, pH, water level and pump\/blower status for rapid alarm and control Daily Portable verification of tank inlet\/outlet DO, temperature, behaviour, flow and feed record Weekly or load-based TAN, nitrite, nitrate, alkalinity and TSS for biofilter and water-renewal trends Periodic Source water, microbiology, hardness, iron\/manganese, chloride and instrument calibration Post-event Root-cause analysis after alarms, mortality, feed stoppage or chemical treatment \u00a0 Read more about:\u00a0Energy Efficiency, Redundancy and Emergency Design in RAS Monitoring principle: A sensor is not enough. Define its location, calibration interval, alarm threshold, responsible person and the action required after an alarm. Frequently asked questions What is the most important RAS water-quality parameter? DO is often the fastest-changing critical parameter, but it is not sufficient alone. CO\u2082, TAN, nitrite, pH, alkalinity, temperature and flow must be managed together. Why can fish be stressed when TAN is normal? Possible causes include low DO, high CO\u2082, nitrite, temperature, suspended solids, gas supersaturation or disease. Does falling pH prove that the biofilter is working? Nitrification consumes alkalinity and can lower pH, but source water, CO\u2082 and chemical dosing also affect it. Interpret pH with TAN, nitrite and alkalinity. Does UV prevent every disease? No. UV only reduces free microorganisms that pass through the unit at the required dose. Quarantine, hygiene, stock management and veterinary oversight remain necessary. FOR YOUR PROJECT: To design species-specific water-quality targets, sensor points, alarm thresholds and treatment capacity, Contact Atlas Aqua.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4442","post","type-post","status-publish","format-standard","hentry","category-genel"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 - ATLAS AQUA Teknoloji<\/title>\n<meta name=\"description\" content=\"A technical guide to dissolved oxygen, pH, alkalinity, TAN, nitrite, nitrate, CO\u2082, temperature and solids management in RAS.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co\u2082\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 - ATLAS AQUA Teknoloji\" \/>\n<meta property=\"og:description\" content=\"A technical guide to dissolved oxygen, pH, alkalinity, TAN, nitrite, nitrate, CO\u2082, temperature and solids management in RAS.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co\u2082\/\" \/>\n<meta property=\"og:site_name\" content=\"ATLAS AQUA Teknoloji\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-19T19:04:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-21T16:14:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3-.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"AAT\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AAT\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/\"},\"author\":{\"name\":\"AAT\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/person\/7cbb558ee42fede4d8ddbeb6b4028075\"},\"headline\":\"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082\",\"datePublished\":\"2026-08-19T19:04:52+00:00\",\"dateModified\":\"2026-08-21T16:14:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/\"},\"wordCount\":949,\"publisher\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp\",\"articleSection\":[\"Genel\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/\",\"url\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/\",\"name\":\"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 - ATLAS AQUA Teknoloji\",\"isPartOf\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp\",\"datePublished\":\"2026-08-19T19:04:52+00:00\",\"dateModified\":\"2026-08-21T16:14:00+00:00\",\"description\":\"A technical guide to dissolved oxygen, pH, alkalinity, TAN, nitrite, nitrate, CO\u2082, temperature and solids management in RAS.\",\"breadcrumb\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage\",\"url\":\"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp\",\"contentUrl\":\"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Anasayfa\",\"item\":\"https:\/\/atlasaqua.com.tr\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#website\",\"url\":\"https:\/\/atlasaqua.com.tr\/en\/\",\"name\":\"ATLAS AQUA Teknoloji\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/atlasaqua.com.tr\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#organization\",\"name\":\"ATLAS AQUA Teknoloji\",\"url\":\"https:\/\/atlasaqua.com.tr\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2025\/07\/atlasaqua-01-1.png\",\"contentUrl\":\"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2025\/07\/atlasaqua-01-1.png\",\"width\":2017,\"height\":880,\"caption\":\"ATLAS AQUA Teknoloji\"},\"image\":{\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/person\/7cbb558ee42fede4d8ddbeb6b4028075\",\"name\":\"AAT\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/7a22b0f3bfb0adc2c737678838f2a0831f07a07588141e1bc606c7f1cc4c4e00?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/7a22b0f3bfb0adc2c737678838f2a0831f07a07588141e1bc606c7f1cc4c4e00?s=96&d=mm&r=g\",\"caption\":\"AAT\"},\"sameAs\":[\"http:\/\/atlasaqua.com.tr\"],\"url\":\"https:\/\/atlasaqua.com.tr\/en\/author\/aat\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 - ATLAS AQUA Teknoloji","description":"A technical guide to dissolved oxygen, pH, alkalinity, TAN, nitrite, nitrate, CO\u2082, temperature and solids management in RAS.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co\u2082\/","og_locale":"en_US","og_type":"article","og_title":"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 - ATLAS AQUA Teknoloji","og_description":"A technical guide to dissolved oxygen, pH, alkalinity, TAN, nitrite, nitrate, CO\u2082, temperature and solids management in RAS.","og_url":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co\u2082\/","og_site_name":"ATLAS AQUA Teknoloji","article_published_time":"2026-08-19T19:04:52+00:00","article_modified_time":"2026-08-21T16:14:00+00:00","og_image":[{"width":1500,"height":1000,"url":"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3-.webp","type":"image\/webp"}],"author":"AAT","twitter_card":"summary_large_image","twitter_misc":{"Written by":"AAT","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#article","isPartOf":{"@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/"},"author":{"name":"AAT","@id":"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/person\/7cbb558ee42fede4d8ddbeb6b4028075"},"headline":"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082","datePublished":"2026-08-19T19:04:52+00:00","dateModified":"2026-08-21T16:14:00+00:00","mainEntityOfPage":{"@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/"},"wordCount":949,"publisher":{"@id":"https:\/\/atlasaqua.com.tr\/en\/#organization"},"image":{"@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage"},"thumbnailUrl":"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp","articleSection":["Genel"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/","url":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/","name":"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 - ATLAS AQUA Teknoloji","isPartOf":{"@id":"https:\/\/atlasaqua.com.tr\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage"},"image":{"@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage"},"thumbnailUrl":"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp","datePublished":"2026-08-19T19:04:52+00:00","dateModified":"2026-08-21T16:14:00+00:00","description":"A technical guide to dissolved oxygen, pH, alkalinity, TAN, nitrite, nitrate, CO\u2082, temperature and solids management in RAS.","breadcrumb":{"@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#primaryimage","url":"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp","contentUrl":"http:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2026\/08\/atlas-aqua-kapali-devre-filtre-35m3--1024x683.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/atlasaqua.com.tr\/en\/2026\/08\/19\/water-quality-management-in-ras-do-ph-tan-nitrite-nitrate-and-co%e2%82%82\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Anasayfa","item":"https:\/\/atlasaqua.com.tr\/en\/"},{"@type":"ListItem","position":2,"name":"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082"}]},{"@type":"WebSite","@id":"https:\/\/atlasaqua.com.tr\/en\/#website","url":"https:\/\/atlasaqua.com.tr\/en\/","name":"ATLAS AQUA Teknoloji","description":"","publisher":{"@id":"https:\/\/atlasaqua.com.tr\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/atlasaqua.com.tr\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/atlasaqua.com.tr\/en\/#organization","name":"ATLAS AQUA Teknoloji","url":"https:\/\/atlasaqua.com.tr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2025\/07\/atlasaqua-01-1.png","contentUrl":"https:\/\/atlasaqua.com.tr\/en\/wp-content\/uploads\/sites\/12\/2025\/07\/atlasaqua-01-1.png","width":2017,"height":880,"caption":"ATLAS AQUA Teknoloji"},"image":{"@id":"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/person\/7cbb558ee42fede4d8ddbeb6b4028075","name":"AAT","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/atlasaqua.com.tr\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/7a22b0f3bfb0adc2c737678838f2a0831f07a07588141e1bc606c7f1cc4c4e00?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7a22b0f3bfb0adc2c737678838f2a0831f07a07588141e1bc606c7f1cc4c4e00?s=96&d=mm&r=g","caption":"AAT"},"sameAs":["http:\/\/atlasaqua.com.tr"],"url":"https:\/\/atlasaqua.com.tr\/en\/author\/aat\/"}]}},"rttpg_featured_image_url":null,"rttpg_author":{"display_name":"AAT","author_link":"https:\/\/atlasaqua.com.tr\/en\/author\/aat\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/atlasaqua.com.tr\/en\/category\/genel\/\" rel=\"category tag\">Genel<\/a>","rttpg_excerpt":"Water Quality Management in RAS: DO, pH, TAN, Nitrite, Nitrate and CO\u2082 Water quality in RAS is a network of interacting processes. Temperature and pH control the toxic NH\u2083 fraction of TAN; alkalinity supports biofilter pH stability; CO\u2082 affects oxygen use; and solids increase microbial oxygen demand and disease pressure. Why is water quality central&hellip;","_links":{"self":[{"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/posts\/4442","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/comments?post=4442"}],"version-history":[{"count":14,"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/posts\/4442\/revisions"}],"predecessor-version":[{"id":4481,"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/posts\/4442\/revisions\/4481"}],"wp:attachment":[{"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/media?parent=4442"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/categories?post=4442"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/atlasaqua.com.tr\/en\/wp-json\/wp\/v2\/tags?post=4442"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}